Trying to Upload a Plc Program Update and It Says Impossible
Downloading/Uploading a Project
Earlier you tin can admission the controller, you lot must establish PC-PLC communications.
After establishing communications:
-
Click the PLC tab on the program ribbon, click Download or Upload, and then select the desired pick.
| Download Options | ||
| Total Download | Compares the projection in the PC to the project in the controller; downloads only the differences, including Media folders | |
| Logic only | Downloads the project without Media folders | |
| Media only | Downloads but the contents of the Media folders | |
| Full download with Upload | Select this choice if you desire to enable project upload. | |
| Logic only with Upload | Select this option if y'all desire to enable project upload. | |
| Download all | This downloads the complete project, overwriting the entire project in the PLC. Notation that it does not include the ability to upload the project. | |
| Export Project to a USB Storage Device | Select this to export the complete project to a USB storage device such as a DOK connected to your PC.
To download the project from DOK, insert the DOK into a UniStream USB port, and then, in UniApps, select System>User App Upgrade>Import Application. Annotation that the model and Bone of the UniStream units must be identical. | |
The network Discovery utility will begin to search for UniStream devices; click the method USB or Ethernet, and then click the desired device to begin download.
Download via USB
Download via Ethernet
Ethernet, or IP Favorites, is a global file that is available in all of your UniLogic projects.
| Note |
|
PLC Restart afterwards Download
When you edit an existing program and download it to the same controller, the controller may crave restart. The PLC volition require restart if:
-
The project in the PLC is completely different (different ID) from the project being downloaded.
-
Plan aspects are inverse that are not HMI, Ladder, or Data Tags, such every bit Communications or Hardware Configuration.
-
The following changes are made in Data Tags:
- If a Tag was deleted
- If Tag is assigned to a unlike Information Type
- If a Tag had its size reduced (for example, in an array or a cord)
- If a Tag address was changed
- If a Tag was changed from Retained to Non-retained, and vice-versa
Note that after a firmware update, the controller may need to be turned off and on (powering-off and powering-on).
Signature Log
You tin view the Signature log containing the history of your project by selecting the Tools> Signature icon on the UniLogic ribbon.
Depending on your version of Windows, you may need to install the USB drivers manually in order to found UniStream - PC communications.
Note that you can simply cull to connect to UniStream via Ethernet for application download, Online Test fashion, etc, thereby skipping the need to install USB drivers.
Under Windows 7, the USB driver installs automatically without issues.
Windows XP
Windows viii/10
If the drivers are installed, but you are yet unable to plant UniStream - PC communications via USB, check if your PC is running programs that control the office of your PC USB port.
If this is the case, yous may need to suspend the program or un-install it.
If the procedures above do not work, please contact Support.